CCCX CEQEL CRITICAL CX
USPTO 630 — Live / Pending
Goods & Services (WIPO Nice Classification)
Recommissioning services for an existing building, namely, testing of facility equipment and software systems in the fields of data centers and advanced manufacturing; Recommissioning services for an existing building, namely, design review and criteria development of data center facility equipment and software systems, server hardware, server rack infrastructure, cooling systems, chilled water systems, computer room air conditioning units, computer room air handling units, power distribution units, uninterruptible power supply systems, electrical switchgear, backup generator systems, building management systems, and environmental monitoring systems, factory acceptance testing, site acceptance testing, integrated systems testing, performance verification, system performance evaluation, facility equipment optimization, energy efficiency improvements, and equipment documentation updates; Building systems and components commissioning services of an existing building, namely, pre-design and design submittal and review of data center facility equipment and software systems, server hardware, server rack infrastructure, cooling systems, chilled water systems, computer room air conditioning units, computer room air handling units, power distribution units, uninterruptible power supply systems, electrical switchgear, backup generator systems, building management systems, factory acceptance and witness testing, site acceptance, equipment delivery and installation, equipment start-up and controls integration, functional testing, and integrated systems testing.
Commissioning services during construction of a building, namely testing of facility equipment and software systems in the fields of data centers and advanced manufacturing; Commissioning services during construction of a building, namely, design review and criteria development of data center facility equipment and software systems, server hardware, server rack infrastructure, cooling systems, chilled water systems, computer room air conditioning units, computer room air handling units, power distribution units, uninterruptible power supply systems, electrical switchgear, backup generator systems, building management systems, and environmental monitoring systems, factory acceptance testing, site acceptance testing, integrated systems testing, performance verification, system performance evaluation, facility equipment optimization, energy efficiency improvements, and equipment documentation updates; Building systems and components commissioning services during construction of a building, namely, pre-design and design submittal and review of data center facility equipment and software systems, server hardware, server rack infrastructure, cooling systems, chilled water systems, computer room air conditioning units, computer room air handling units, power distribution units, uninterruptible power supply systems, electrical switchgear, backup generator systems, building management systems, factory acceptance and witness testing, site acceptance, equipment delivery and installation, equipment start-up and controls integration, functional testing, and integrated systems testing.
Mark / Design Description: The mark consists of three nested stylized letter Cs, two in blue and the interior one in black, followed by a stylized letter X in black, above the words CEQEL Critical Cx in stylized fonts with CEQEL in blue and Critical Cx in black.
Global Jurisdiction & Nice Class Footprint
Primary Office: United States (USPTO) · Nice Classes: 37,42
Visually & Phonetically Similar Marks Globally
| Risk | Mark | Office & Status | Score |
|---|---|---|---|
| Low Risk | MISSION CRITICAL IOT US 50036336 | US Live / Pending | 50% |
| Low Risk | LE CYCLE CREATIVE CLUB FR 4641278 | FR Live / Registered | 48% |
| Low Risk | CELLCORTEX US 99671833 | US Live / Pending | 48% |
| Low Risk | CASE CLARITY AI US 99931963 | US Live / Published | 47% |
| Low Risk | GALAXY CONCRETE COATINGS US 99800076 | US Live / Pending | 45% |
| Low Risk | Hubert Cloix FR 4623346 | FR Live / Registered | 42% |
Prosecution & Register History
| Date | Code | Event |
|---|---|---|
| 2026-06-20 | NWAP | NEW APPLICATION ENTERED |
| 2026-06-20 | MAFR | APPLICATION FILING RECEIPT MAILED |
| 2026-11-20 | NWOS | NEW APPLICATION OFFICE SUPPLIED DATA ENTERED |